D10 Expert Parts Counting And Checking

Ball bearings fall through the 16-beam light screen, created by the fiber optic pair. Bearings are counted using one of the D10 Expert sensor outputs. The second D10 Expert is programmed to stop the feeder mechanism, if more than two beams are ever broken (indicating an oversized bearing).


Objective:
To count parts which exit a vibratory feeder, and to monitor for oversize parts

Sensor Models:
Model D10DNFP (with dual discrete outputs)

Fiber Optic Models:
One pair of model PIRS1X166 UMPMAL16-beam linear array individual plastic fiber optics.

ÀÚ·áÃâó : BANNER

  0
3500
¹øÈ£     ±Û Á¦ ¸ñ ÀÀ¿ëºÐ¾ß ÀÛ¼ºÀÏ Á¶È¸
288
D12 Expert Sensing Inverted IC Chips Àü±âÀüÀÚ, ±â°è, È­ÇÐ 2003-02-15 1182
287
D12 Expert Perforated Bag Detection Àü±âÀüÀÚ, ±â°è, È­ÇÐ 2003-02-15 998
286
D12 Expert IC Chip Inspection Àü±âÀüÀÚ, ±â°è, È­ÇÐ 2003-02-15 1092
285
D10 Expert Parts Counting And Checking Àü±âÀüÀÚ, ±â°è, È­ÇÐ 2003-02-15 1652
284
Safety Switches - Two Piece Cover with Flexible In-Line Actu.. Àü±âÀüÀÚ, ±â°è, È­ÇÐ 2003-02-15 1099
283
Safety Switches - Standard Access Door Using Flat Packs Àü±âÀüÀÚ, ±â°è, È­ÇÐ 2003-02-15 1026
282
Safety Switches - Hinged Access Door Using Hinged Lever Actu.. Àü±âÀüÀÚ, ±â°è, È­ÇÐ 2003-02-15 1128
281
FI22 Non-Contact Sensing of Liquid in Transparent Tubing Àü±âÀüÀÚ, ±â°è, È­ÇÐ 2003-02-15 1181
280
EZ-BEAM Fill Level Àü±âÀüÀÚ, ±â°è, È­ÇÐ 2003-02-15 1157
279
ULTRA-BEAM Bin Fill Level Àü±âÀüÀÚ, ±â°è, È­ÇÐ 2003-02-14 1112
278
Q45U Pump-in Pump-out Àü±âÀüÀÚ, ±â°è, È­ÇÐ 2003-02-14 1110
12345678910,,,36