°³ÀÎȸ¿ø ±â¾÷ȸ¿ø

 º¸¾ÈÁ¢¼Ó
ȸ¿ø°¡ÀÔ £ü ºñ¹øºÐ½Ç

  Quick Menu  
±â¼ú¹®´ä½Ç
¼¾¼­°ü·Ã±â»ç
¼¾¼­¸Å¸ÅÀåÅÍ
¼¾¼­ºÐ·ùÇ¥
°øÁö»çÇ×
ÀÚÁÖÇÏ´Â Áú¹®
Áú¹®´äº¯°Ô½ÃÆÇ

 Market
¼¾¼­¸Å¸ÅÀåÅÍ
±â¾÷ȸ¿ø»ç°¡ º¸À¯ÁßÀÎ Á¦Ç°(½ÅÁ¦Ç°, Àç°íÇ° µî)À» µî·ÏÇÏ¿©
¼ö¿äÀÚ¿Í Á÷°Å·¡ÇÏ´Â ½ÃÀåÀÔ´Ï´Ù.
¤ýÀÛ¼ºÀÏ 2007-01-16
¤ý÷ºÎ#2 1168926912.jpg (0KB) (Down:0)
¤ýÆǸÅȸ»ç SHARP
¤ýÁ¦Á¶È¸»ç SHARP
¤ýÆǸŴܰ¡ 15000
¤ýº¸À¯¼ö·® 4
¤ýÀÀ¿ëºÐ¾ß Àü±âÀüÀÚ
¤ýÁ¶È¸: 10765      
[SHARP] Àû¿Ü¼± ¼¾¼­ GP2D15 , GP2Y0D02YK

ÈçÈ÷ °ø´ë Á¹¾÷ÀÛÇ°¿¡¼­ ¸¹ÀÌ ¾²´Â Àû¿Ü¼±¼¾¼­ÀÔ´Ï´Ù.

»þÇÁ»çÀÇ GP2D15 Infrared Ranger   ÀÔ´Ï´Ù.

°£´ÜÈ÷ ¸»ÇØ 24Cm À̳»ÀÇ ¹°Ã¼¸¦ °¨ÁöÇØ µðÁöÅÐ ½ÅÈ£(5volt)·Î Ãâ·ÂÇØÁÝ´Ï´Ù.~~

µ¥ÀÌÅÍ ½ÃÆ®¿Í ÄÉÀ̺í(25Cm) °°ÀÌ º¸³»µå¸³´Ï´Ù. »ç¿ë±â°£Àº 1°³¿ùÁ¤µµ±¸¿ä. Àß ÀÛµ¿ÇÕ´Ï´Ù..

½Î°Ô »ì¼ö Àִ±âȸÀÌ´Ï  ¼­µÑ·¯ ±¸ÀÔÇϼ¼¿ä~~



ÀÌ¿Ü¿¡µµ GP2Y0D02YK µµ °¡ Àִµ¥¿ä À̼¾¼­´Â 80Cm À̳»ÀÇ Àå¾Ö¹°À» °¨ÁöÇؼ­ µðÁöÅÐ ½ÅÈ£·Î Ãâ·ÂÇØÁÝ´Ï´Ù.
°¡°ÝÀº °³´ç 20000¿øÀÔ´Ï´Ù.


¹®ÀÇ »çÇ×ÀÖÀ¸½Ã¸é angel3rd@nate.com ³×ÀÌÆ®¿Â ¸Þ½ÅÁ®·Î ÂÊÁö Áֽðųª 010-3077-ÆÈÀÏÀÏ»ï À¸·Î ¹®ÀÚ ÁÖ¼¼¿ä~ Ä£ÀýÈ÷ ´äº¯ÇØ µå¸³´Ï´Ù.

¾Æ·¡´Â GP2D15 Ư¡ÀÔ´Ï´Ù.

GP2D15 Infrared Ranger




Less influence on the color of reflected objects, reflectivity
Simple logic interface
Detecting range preset to 24 cm
External control circuit unnecessary
Low cost


This sensor takes a continuous distance reading and reports the distance as a logic value with a pre-set distance range of 24 cm.  The interface is 3-wire with power, ground and the output voltage and requires a JST 3-pin connector which is included with each detector package.  Each package also includes a booklet that contains specifications, describes plugging together the connector, interfacing the detector, and application notes describing using the GP2D15.

Absolute Maximum Ratings
Parameter Symbol Rating Unit Remarks
Supply Voltage VCC -0.3 to +7 V  
Output Terminal Voltage VO -0.3 to VCC+0.3 V Open collector Output
Operating Tempurature Topr -10 to +60 ¡ÆC  
Storage Tempurature Tstg -40 to +70 ¡ÆC  


Operating Supply Voltage
Parameter Symbol Rating Unit Remark
Operating Supply Voltage VCC 4.5 to 5.5 V  


Electro-Optical Characteristics
Parameter Symbol Conditions Min. Typ. Max. Unit
Measuring distance range delta L *1*3 10 - 80 cm
Output Terminal Voltage VOH Output voltage at high level *1 VCC - 0.3 - - V
Output Terminal Voltage VOL Output voltage at low level *1 - - 0.5 V
Output difference characteristics VO *1, *2, *4 21 24 27 cm
Average supply current Icc   - 33 50 mA

L: Distance to reflected object
*1 Using reflected object: White paper (Made by Kodak Co. Ltd. gray cards
     R-27, white face, reflective ratio: 90%)
*2 Device shipped after the following adjustment:
     Output switching distance L=24cm +-3cm
*3 Possible distance measurement range (of the sensor optics)
*4 Output switching has a hysteresis width. The distance specified by Vo
     should be the one with which the output L switches
     to the output H.



Complete package including detector, connector, and booklet.
               Price: 17,000 Won,            Part Number: R49-IR15


You can find the Sharp datasheet in PDF format here.



  0
3500
¹øÈ£     »ó Ç° ¸í ÆǸÅȸ»ç ÀÛ¼ºÀÏ Á¶È¸
86
[SHARP] Àû¿Ü¼± ¼¾¼­ GP2D15 , G.. SHARP 2007-01-16 10765
85
·ÎŸ¸®¿£ÄÚ´õ [3] (ÁÖ)ÇÑ¿µ³Ë½º 2004-01-06 6059
84
Àü·ù¼¾¼­ ¼¼¸®Åõºñ 2006-11-16 5528
83
Àû¿Ü¼± ÀÎü°¨Áö ¼¾¼­ °³ÀÎ 2007-07-04 5140
82
co2 sensor ¼ºÁø»ó»ç 2006-06-10 5129
81
LH-10 ºñÄ«(WIKA) 2007-02-02 4863
80
½Àµµ¼¾¼­ [2] ½ãÅØ(ÁÖ) 2003-12-11 4501
79
ÀÎü°¨Áö¼¾¼­ ¸ðµâ (ÁÖ)¾Æ¸®¿¤ »ó»ç 2008-11-26 4372
78
humidity sensor ½Àµµ¼¾¼­ sungjin corp 2006-03-03 4311
¼¾¼­¸Å¸ÅÀåÅÍ ÀÌ¿ë¾È³» 2003-02-04 4288
76
µ¿ÀÛ°¨Áö¼¾¼­ (ÁÖ)ÅÚÆ®·Ð 2009-02-27 4228
75
ÃÊÀ½ÆÄ ·¹º§¼¾¼­, ¼öÀ§°è,°Å¸®Ãø.. À¯´Ð½º 2004-07-05 4219
74
Çʸ§Çü Leak sensor <¹°.ÄÉÀÌ.. (ÁÖ)À¯¹Î¿¡¾²Æ¼ 2009-11-12 3957
73
µðÁöÅнdz»¿ÂµµÁ¶Àý±â [1] ±¸·úÀü±â 2003-02-21 3934
72
ÀÚÀ̷μ¾¼­¸¦ Á¾·ùº°·Î »ç°í½Í½À.. * 2005-01-11 3553
71
±ÙÁ¢½ºÀ§Ä¡ À¯·Î»ó»ç 2003-04-28 3412
123456